CSG SIP Communications Gateway
2
CSG SIP Communications Gateway Operation/Reference Guide
CSG Specifications
The following table lists the specifications for the CSG.
CSG Specifications
Dimensions (HWD):
1.74” x 11.45” x 5.44” (4.41 cm x 29.09 cm x 13.82 cm)
Weight:
2.25 lbs (1.02 kg)
Enclosure
Metal with black matte finish
Power Requirements
Constant current draw: 2.6 A @ 12 VDC
Memory
• 8MB on board serial Flash memory
• 64MB 16-bit parallel SDRAM
Certifications
FCC (Class A), CE, IEC60950, and RoHS
Operating/Storage
Environment
• Operating Temperature: 0° C (32° F) to 40° C (104° F)
• Operating Humidity: 5% to 85% RH Non-Condensing
• Storage Temperature: -20° C (-4° F) to 70° C (158° F)
• Storage Humidity: 0% to 85% RH Non-Condensing
Front Panel Components:
Power LED
Indicates whether the unit is turned on and receiving power.
Network LED
Indicates whether a network cable is connected and the speed of the network.
IP Phones LEDs
Indicates whether the corresponding link is connected and the speed of the
link.
Analog LEDs
Indicates whether the analog port is installed and the type of port (FXO/FXS)
installed. (Not available on all models.)
Rear Panel Components:
Power connector
5.1mm OD, 2.1mm pin, 12V 3.0A center positive
Configuration Reset Switch
Resets the current configuration to the factory default when pressed
continuously during the boot process.
Console port
1 RJ45 port for console (craft) port serial control
Network port
1 RJ45 10/100baseT port for a general (WAN) connection
IP Phones ports
4 RJ45 10/100baseT ports for IP phone connections
Analog ports
• 8 RJ11 ports: 4 for FXO and 4 for FXS connections
(CSG-544 only)
• 8 RJ11 ports for FXO connections (CSG-580 only)
Note
: The CSG-500 does not use analog ports.
Compatible Devices
• MVP-8400i
• NXD-500i
• NXD-700Vi
• NXD-1000Vi
• MVP-5200i
• MET-ECOM Metreau Entry Communicator
Included Accessories
• PSN3.0 Power Supply, 3.0A, 12.0VDC (
FG423-31
)
• CSG SIP Communications Gateway Installation Guide (
93-2182-01
)
• 2 Surface mounting brackets (
62-2182-04
)
• 4 #4-40 X .250 PPH screws (
80-0112
)
Other AMX Equipment
• DIN Rail Mounting Bracket (
FG532-06
)
Summary of Contents for CSG-500
Page 4: ...Safety Certification and Agency Approvals iv CSG SIP Communications Gateway ...
Page 8: ...viii CSG SIP Communications Gateway Operations Reference Guide Table of Contents ...
Page 12: ...CSG SIP Communications Gateway 4 CSG SIP Communications Gateway Operation Reference Guide ...
Page 22: ...Installation 14 CSG SIP Communications Gateway Operation Reference Guide ...
Page 83: ...Device Configuration 75 CSG SIP Communications Gateway Operation Reference Guide ...