![background image](http://html.mh-extra.com/html/amx/axb-tmc/axb-tmc_instruction-manual_2937419037.webp)
Programming
33
AXB-TMC/TMX+ Television Managers
The following table lists the stop and data bit settings used with the SU command.
The following table lists the parity settings used with the SU command.
The following table shows the baud rate settings used with the SU command.
RS-232 Send_Commands (Cont.)
SU
Sets the communication
parameters for the
AXB-TMC/TMX+.
Syntax:
"'SU',<value>"
Variable:
<Value> = See FIG. 16 and the following tables.
Example:
SEND_COMMAND AXBTMX,"'SU',255"
Sets the AXB-TMC/TMX+ communication settings to 38, 4K baud, no parity,
8 data bits, 1 stop bit.
FIG. 16
'
SU
'
Send_Command bit values
Stop and Data Bit Settings
Value
Bit Settings
Bit
1
0
Stop bits
0
1 bit
2 bits
Data bits
1
8 bits
7 bits
Parity Settings
Bits
Parity
2
3
4
Space
0
1
1
Mark
0
0
1
Even
1
0
1
Odd
0
1
1
None
1
1
1
Baud Rate Settings
Bits
Baud rates
5
6
7
300
0
0
0
600
1
0
0
1,200
0
1
0
2,400
1
1
0
4,800
0
0
1
7
6
5
4
3
2
1
0
Baud
Parity
Data
Stop