![AMX AXB-TMC Instruction Manual Download Page 23](http://html.mh-extra.com/html/amx/axb-tmc/axb-tmc_instruction-manual_2937419023.webp)
Programming
19
AXB-TMC/TMX+ Television Managers
Programming
You can program the AXB-TMC/TMX+ to perform a wide variety of operations using Axcess
Send_Commands. This section describes channel settings, IR functions, system, AXB-TMC clock,
and RS-232 mode Send_Commands. Refer to the
Axcess Programming Language
manual for
additional programming information.
Channel Setting Commands
The AXB-TMC/TMX+ use the channel setting commands listed in the following table.
!
Activating a channel (IR/Serial function) will deactivate the channel that is on.
!
Contact closure inputs on I/O 1 through I/O 4 will also generate PUSHes and RELEASEs
on channels 251 through 254, respectively.
Channel Settings
Channel Function
1
Generates IR/Serial function 1, else off.
2-127
Channels that generate IR code for the corresponding functions.
128-246
Push and release channels for received IR code.
247
Generates PUSH when the AXB-TMC/TMX+ powers up, if firmware version 2.28 or newer is
loaded.
248
A push on this channel indicates a power failure error.
249
Response LED blinks when channels 249 and 250 are on.
AXB-TMC Only: A push and release on this channel indicates that the countdown timer has
counted down to zero.
250
Response LED lights when channel is on.
AXB-TMC Only: A push and release on this channel indicates that a scroll has completed. This
occurs after all the trailing blanks (plus one) have scrolled off the display.
251
I/O 1 is on (switch to GND) when channel is on.
252
I/O 2 is on (switch to GND) when channel is on.
253
I/O 3 is on (switch to GND) when channel is on.
254
I/O 4 is on (switch to GND) when channel is on.
255
Channel is on if CC-XPS External Frequency Scan Sensor detects horizontal scan frequency.