![AMX AXB-TMC Instruction Manual Download Page 16](http://html.mh-extra.com/html/amx/axb-tmc/axb-tmc_instruction-manual_2937419016.webp)
Installation
12
AXB-TMC/TMX+ Television Managers
Television Power Receiver (CC-XPS) Adjustment
After connecting the Television Power Receiver (CC-XPS) to the television, the Auxiliary DIP
switch settings may require resetting to detect when the television's power is on or off.
The Auxiliary DIP Switch Settings 7 - 8 and Values for IR table on page 4 shows the high, medium,
and low sensitivity.
The simplest operation response test is to use the Axcess terminal and send multiple SP commands
to the AXB-TMC/TMX+. In most Synergy systems, this can be accomplished by pressing Source
up and down on the hand-held remote.
Mounting Options
Surface-Mount installation
Installing angle mounting brackets
To install the angle brackets on the AXB-TMC/TMX+:
1.
Position the side of the angle-mounting bracket (with two holes) against the side of the
AXB-TMC/TMX+. Then, align the two bracket holes with the two threaded screw holes in the
side of the AXB-TMC/TMX+.
2.
Insert two of the four flat-head screws provided, and start the screws. Using a Phillips-head
screwdriver, tighten the screws.
3.
Repeat steps 1 and 2 for the second mounting bracket.
Before making IR signal strength adjustments, attempt to correct the problem by
adjusting the values of the Send_Commands CTON and CTOF. Refer to the
Programming section on page 19 for more information.
FIG. 14
AXB-TMC/TMX+ flat mount installation using optional angle brackets