![background image](http://html.mh-extra.com/html/amx/axb-tmc/axb-tmc_instruction-manual_2937419027.webp)
Programming
23
AXB-TMC/TMX+ Television Managers
System Send_Commands (Cont.)
DK
Deletes all direct connec-
tions set with the DC
command.
Syntax:
'DK'
Example:
SEND_COMMAND AXBTMX,'DK'
Deletes all direct connections set with the DC command.
PIF
Disables PIN command.
Syntax:
'PIF'
Example:
SEND_COMMAND AXBTMX,'PIF'
Disables PIN command.
PIN
Determines TV status.
Syntax:
'PIN'
Example:
SEND_COMMAND AXBTMX,'PIN'
Turns on the function to check I/O 1 and the frequency sensor to determine
actual TV status. I/O 2 will follow PON and POF commands. The status of this
function is stored in permanent memory until changed.
POD
Disables current PON or POF
command settings.
Syntax:
'POD'
Channel 255 changes are enabled.
Example:
SEND_COMMAND AXBTMX,'POD'
Disables current PON (power on) or POF (power off) command settings.
POF
Sends IR function 28 to turn
device power off.
Syntax:
'POF'
Sends IR function 28 (if available) to turn device power off. If after three
attempts, the CC-XPS (power sensor) still detects a power-on status, the
television controller starts processing stored buffer commands. Then, if
another IR function 28 fails to turn the television's power off, the television con-
troller sends a PUSH and RELEASE to channel 248 and generates a power
failure error.
If the device is turned on manually, this command turns television power off
unless the television controller receives a PON (power on) or POD (disable
POF) command.
Example:
SEND_COMMAND AXBTMX,'POF'
Sends IR function 28 (if available) to turn device power off.
PON
Sends IR function 27 to turn
device power on.
Syntax:
'PON'
Sends IR function 27 (if available) to turn device power on. After three
attempts, if the power sensor (CC-XPS) still detects a power-off status, the
television controller starts processing stored buffer commands. If another IR
function 27 fails to turn the television's power on, the television controller sends
a PUSH and RELEASE to channel 248 and generates a power failure error. If
the device is turned off manually, this command turns television power on
unless the television controller receives a 'POF' (power off) or 'POD' (disable
'PON' command) command.
Example:
SEND_COMMAND AXBTMX,'PON'
Sends IR function 27 (if available) to turn device power on.