Installing a CP-15 Remote Control Panel
27
CP-15 Instruction Manual
Installing a CP-15 Remote Control Panel
This section covers rack installation for the CP-15 Remote Panel, as well as instructions for linking
multiple panels. When the installation is complete, perform a test switch to make sure the system is
working properly (see page 32).
General Specifications
Rear View
Caution:
The Service connector is not to be used as a point of control. It should be used for service
only as directed by AMX technical support.
Connecting to an AMX AutoPatch Router
Communication Cable Requirements
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield, such as Alpha 2412C
(customer supplied)
Maximum length of cable: 1,000 ft. (304 m) total, including linked panels
Parameter
Value
Cable for XNNet Communications
Two-conductor, 20 AWG, 7/28 strand cable with a drain wire or shield,
such as Alpha 2412C (customer supplied)
Distance: 1000 ft. (304.8 m) total, including linked panels
Power
+24 volt DC @
≥
600 mA
Humidity
0 to 90% non-condensing
Dimensions
0.97 in. (2.46 cm) depth
19.0 in. (48.26 cm) width with mounting ears
3.50 in. (8.89 cm) height, 2 RU
Weight
Approximately 1 lb 10 oz (0.74 kg) per panel
FIG. 8
Rear view of CP-15 Remote Panel
Service connector – do
not
use as a point of control
Power connectors
Comm Link connectors