Encoder Configuration Options
34
N2000 Series User Manual
RS232 Settings
The section of the
Settings
page shown in
Figure 5
is displayed when you click the
RS232 Settings
link. Options are described in
Table 3
.
FIG. 5
RS232 Settings
Network Setup Section
The
Network Setup
section of the
Settings
page is shown in
Figure 6
. Options are described in
Table 4
.
FIG. 6
Network Setup Section
Enable SNMP
Enable to allow the device to handle Simple Network
Management Protocol (SNMP) queries.
Relaxed Analog Input
Timing
Enable to allow small variances in the analog input (to
avoid video interruption).
TABLE 2
Settings Page: Advanced Settings (Cont.)
Option
Description
Notes
TABLE 3
Settings Page: RS232 Settings
Option
Description
RS232 Baud Rate
Select the appropriate baud rate for the RS232 serial interface. Default is 9600.
RS232 Data Bits
Select the appropriate data bit count for the RS232 serial interface. Default is 8.
RS232 Parity
Select the appropriate parity for the RS232 serial interface. Default is no parity (
none
).
RS232 Stop Bits
Select the appropriate number of stop bits for the RS232 serial interface. Default is 1.
TABLE 4
Settings Page: Network Setup Settings
Option
Description
Notes
IP Mode
Configure the IP address mode. When set to
AUTO IP
,
an IP Address in the range of 169.254.xxx.xxx with
Netmask
of 255.255.0.0 and
Gateway
address
of
169.254.1.1 will be automatically assigned to the
N2000 Encoder by the control software. When set to
DHCP,
an IP Address in the range of the DHCP server on
the network will be automatically assigned to the
N2000 Encoder. When set to
STATIC
, an
IP address
,
Netmask
, and
Gateway
address
must be manually
entered.
Using
DHCP
is generally not recommended. If the
device is set to
DHCP
and fails to receive an address
from the DHCP server in time, it will revert back to the
AUTO
IP
Address (169.254.xxx.xxx) until the unit is
rebooted.
IP address
View the current IP address of the N2000 Encoder.
When in
STATIC
mode, enter a new IP address into this
field.