BIOFILTER
GB
IMPORTANT SAFETY RULES:
This appliance is a complete biological filtering system for ponds purification, including UVC sterilizer, pump and tube. Any other type of use is not permitted and consequently
it is not covered by the manufacturer’s responsibility.”
NOTE: BEFORE STARTING ANY OPERATION OF USE AND MAINTENANCE OF THE DEVICE, PLEASE READ THE MANUALS OF USE AND MAINTENANCE.
THE MANUFACTURER CANNOT BE HELD IN ANY CASE RESPONSIBLE OF ACCIDENTS OR DAMAGE RESULTING FROM INAPPROPRIATE USE OF THE DEVICE, AS WELL AS EVEN PARTIAL
FAILURE TO OBSERVE THE SAFETY REGULATIONS AND THE INTERVENTION PROCEDURES DESCRIBED IN THE MANUALS.
ATTENTION: THE DEVICE EQUIPMENT CAN BE PUT INTO OPERATION ONLY AFTER IT HAS BEEN CORRECTLY INSTALLED AND CONNECTED AND THAT THE USER HAS PREVIOUSLY READ
THE MANUAL.
CAUTION: This symbol on the product label and on its packaging indicates that this instruction manual must be read carefully before the appliance is started up or ser-
viced. be held responsible for any damage caused by this appliance if you have not read and understood this instruction manual carefully or if you have not followed this.
In order to avoid any type of accident, carefully observe the following warnings (in addition to the most basic safety regulations). This appliance can be used by children
aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision. WARNING: Unplug or switch off all appliances in the aquarium or pond before carrying out maintenance. If the connection plug
of some appliance or the socket are wet, turn off the main switch before disconnecting the power cord of the appliances present.
- The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
- Check the voltage on the device label and ensure it corresponds to the main power supply.
- When the device is plugged to the mains, ensure that the lowest part of the lead is lower than the socket, to avoid any drops of water that are on the lead flowing into the
socket. If the cable is wet, do not touch the plug with your hands and before disconnecting the device, turn the mains switch off.
- We recommend that this device and other electrical aquarium devices should be connected to power supplies with ground fault circuit interrrupters lnd 30 mA.”
Outdoor use: don’t bury the power supply cable, but follow the installation rules provided by the local regulations in force and please consult a qualified electric installer. During
installing the appliance or maintaining it, please don’t lift it using the power cord. Before putting the appliance into operation, make sure you have installed it correctly. Never
carry out repairs or technical modifications to the appliance and use only original spare parts.
CAUTION: avoid direct exposure to sunlight. Do not use if there is a risk of freezing: in winter it is advisable to remove the appliance or operate it only if it is protected against
freezing. The appliance must only work in the presence of water and can not run dry. Do not use for drinking water. Do not use for flammable or explosive, abrasive or corrosive
liquindi. Use only for the treatment of pond or aquarium water.
CAUTION: do not connect to the public water supply (public aqueduct).
ATTENTION: in outdoor use, according to the current IEC 60364-7-702 standard, the minimum safety distance of electrical equipment from swimming pools or swimming ponds
must be 2 meters. Place the appliance and fix it permanently in a place where it is safe from water splashes and protected from flooding.
PRELIMINARY CHECKS
Checking for damage - Verify that the various parts of the device does not display physical damages due to bumps, tears or abrasions.
Check in particular: • That there are no signs or dents, indicative of bumps caused by transport. • The integrity of the the electrical cables.
Damage Reporting Procedure
If any damage is discovered, stop the connection procedure and report the nature of the damage to the Customer care office of the manufacturer.
KEEP THESE INSTRUCTIONS CAREFULLY!
WARNING: these devices contain an emitter of UV-C rays that can damage eyes and skin, improper use or damage to their protections and casings can cause these radiation to
escape, so if these devices are damaged they should not be used they must be discarded immediately.
-CAUTION: it is forbidden to use the UV-C lamp outside the appliance.-WARNING: never look at the UV-C lamp when it is on.
-CAUTION: these devices contain glass. Handle with Care.”
SUBMERSIBLE PUMP INCLUDED - IPX8 protection for working in water immersion:
CAUTION: only this appliance which is part of the AMTRA BIOFILTER SET 6000 kit can be immersed in water up to the maximum depth indicated by the following symbol
m
on the product label. Be sure to respect this warning.
Dear Customer, Thank you for purchasing AMTRA BIOFILTER SET 6000. This practical and compact filter kit combines biological and mechanical filtration with UVC sterilization,
allowing you to purify water and eliminate pathogenic germs and suspended green algae that cause turbidity.
INSTALLATION:
Proceed with the installation of the pump by choosing a part of a pond with a flat surface so that it can not accidentally fall. Connect the supplied hose to the pump outlet and,
if necessary, secure it with a clamp. Place the filter on a flat and stable surface, raised respects the water level of the pond. According to the regulations in force, the electronic
ISTR_BIOFILTER_6000.indd 8
04/01/19 16:43