1.5 The standard installation
Before installing the AMPEE01, you need to calculate the right distance between
the metal detector and the diverter. You can do this with the following formula.
Distance[m]= Transport velocity[m/s]*Reaction time[s]*Safety factor
The Distance is the metal detector to the diverter.
The Transport velocity is the material transport velocity in the pipeline.
The Reaction time is defined as the time taken by diverter to reach activated
position after receiving a switching impulse.
The range of the Safety factor is 1.2~1.3.
The ‘ I ’ in the following figure 5 is a piece of connection pipe, it should be
supplied by customer. The length of the pipe is normally from 2m to 4m,
corresponding to transport velocity from 10m/s to 25m/s;
A) S-02-300-Φ Pipe of spark detectors
B) M-03-374 Metal detector
C)
HD-04-345
Diverter
D) B-05-600 Collecting box
E) MSD-01 Control box
F)
F-08-NM Clamp hoop
G)
NM-07-1200-Φ Glass steel pipe
H) K-06-374-Φ
Square to circular pipe
I)
Connection pipe to be supplied by user
Figure 5
:
Standard Installation of the AMPEE01