AMPEON AMP-Series
~19~
8-bit command consists of 2 ASCII codes
Function Lo
DATA
(
n-1
)
Contents of data
:
n×8-bit data consist of 2n ASCII codes
n<=20,maximum of 40 ASCII codes
(
20 data
)
……
DATA 0
LRC CHK Hi
LRC check sum
:
8-bit check sum consist of 2 ASCII codes
LRC CHK Lo
END Hi
End characters
:
END Hi=CR(0DH)
,
END Lo=LF(0AH)
END Lo
3.3 Functions
03H: multi read, read data from registers
Command message
:
Response message
:
3.4 Address list
Status monitor
Read only
0000H
bit0
1
:
metal is in action
bit1
1
:
the hopper is full
bit7
1
:
Chinese
0
:
English
bit8
1
:
detected the spark
bit15
1
:
the machine works normally
0001H
The speed of detected meta
0002H
Real-time clock of the machine
STX
‘:’
Address
‘0’
‘1’
Function
‘0’
‘3’
Number of data
(count by word)
‘0’
‘8’
0000H
‘8’
‘0’
‘8’
‘0’
0001H
‘0’
‘0’
‘6’
‘9’
0002H
‘1’
‘6’
‘1’
‘5’
0003H
‘0’
‘0’
‘2’
‘3’
LCR Check
‘3’
‘D’
END
CR
STX
‘:’
Address
‘0’
‘1’
Function
‘0’
‘3’
Starting address
‘0’
‘0’
‘0’
‘0’
Number of data
(count by word)
‘0’
‘0’
‘0’
‘4’
LRC Check
‘F’
‘8’
END
CR