AMPEON AMP-Series
~18~
1
)
120 ms, → 6.4 m/s ", this message tells you how long the diverter took to
move from the normal to the activated position and the metal transport velocity just
detected is 6.4 m/s . The arrow symbols
“←
,
→”
show you which kind of the
metal detected(ferrous or non ferrous)
2
)
08 / 21 / 2010
09 : 26 records the time of the latest fire alarm ,press the key
‘►’
, you can turn to the previous fire alarm history.
3
)
Press ‘ESC’ return to the main page.
2.5 Communication setting
There is a built-in RS-485 serial interface, marked J7
is located on the
main board (see figure 9).
When the cursor flashes in NO.5 ‘ 5.com set’ item in parameter setting menu,
you can enter into to the Communication setting page by press ‘FUN’,’
▲
’
simultaneously.
Figure 20 : Communication setting menu
1) Press ‘
▲
,
▼
’ can select the communication address which can be set from
No1 to No.15 .
2
)
RS-485 can be set up to communicate on Modbus networks, baud rate is
19200bit/s,and the communication protocol uses Modbus ASCII mode ,protocol <7
,
N
,
2 >.
3
、
Communication protocol
3.1 10-bit character frame
(
for ASCII
)
Start
bit
0
1
2
3
4
5
6
Stop
bit
Stop
bit
3.2 Communication protocol ASCII mode:
STX
Start character =’:’(3AH)
Address Hi
Communication address
:
8-bit address consists of 2 ASCII codes
Address Lo
Function Hi
Command Code
: