AMPEON AMP-Series
~4~
1) Metal detector can be hung up at the four hoisting rings by metal rods. Metal
detector should be installed firmly, to avoid incorrect detecting caused by the
vibrating.
2) Make sure the shielded cables for signal receiving and transferring between
the metal detector and control box is connected reliably
,
then fix it without
vibrating . Connector cables are part of the sensor and have to be protected against
interferences.
3) Metal detector should keep a certain distance from the things that generate
the electromagnetic radiation such as electric motor, transformer and fluorescent
lamp etc. Furthermore, it should keep a certain distance from big moving metal
object. The cables with big current should be also kept a distance from the detector.
1.3 The installing of control box
A
)
Control box
B
)
Control panel
C
)
Cable Gland
Figure 3
:
Parts and External dimension of control box
Usually the control box is installed on the Support of the collecting box (Figure 4.E). Of
course you can also install control box on the nearby wall .
1.4 The installing of actuator unit
The actuator unit is composed of two parts: diverter and collecting box
(
refer to
Figure 4
)
.The collecting box is installed under the diverter and be careful not to
reversely installed and assure that the collect valve (Figure 4:D) can act flexibly.
Summary of Contents for AMP-EE01
Page 1: ...Ver1 91 2013 10 13...
Page 24: ...AMPEON AMP Series 22...