AMPEON AMP-Series
~16~
Figure 17
:
Function setting menu
Parameter
Settings
Factory setting
1.Sensitivity
0-99 %
69%
2.Activate
0.00s-3.00s
0.00S
3.Reset
1.00s-3.00s
1.50S
Table 3: Function parameter value table
1
)
Sensitivity
①The metal detecting Sensitivity Parameter range is 0-99%,the lowest is 0 and
the highest is 99%. The percentage is higher, the sensor is more sensitive.
②You can set the ‘Sensitivity’ parameter according to the actual requirement.
The value in the range 40-65% can satisfy most of the users in spinning mills.
2
)
Activate
‘Activate’ parameter refers to the additional time by the software from detects
the metal is detected to the diverter is actuated. Use the key
‘◄, ►’
can set the
parameter. The setting precision of the activate parameter is 0.01S and the setting
range is 0.00S-3.00S. If press
‘◄, ►’
for 3 seconds simultaneously, the data would
change continuously.
Warning:
The parameter is closely related to the length of connection pipe and the
Transport, so if it was set improperly, that might cause the diverter acts
incorrectly.
3
)
Reset
‘Reset’ parameter refers to the additional time by the software from the
activated position to the normal position of the movable flap. Use
‘◄, ►’
to set the
parameter of ‘Reset’, the range is 1.00S-3.00S and the setting precision is 0.01S.If
press
‘◄, ►’
simultaneously for 3 seconds, the data would change continuously.
Warning:
If the parameter is set too low, maybe that material including the metal can not
be diverted, but if the parameter is set too high, more contaminated material