AMPEON AMP-Series
~9~
ATTENTION!
We shall avoid the share of power supply with other equipments that may
produce interference radiation. We shall pay special attention to avoiding the
phenomenon that on the time of spark alarm stopping
,
the power supply of
instrument itself can’t be shut down for output of relay signal.
b) Terminal 4
‘NC’ and terminal 5‘CM’ provide a couple of voltage-free normally
closed relay contacts
,
that can be used to control the fan and other production
machinery. (Terminal 5 ‘CM ’ and terminal 6 ‘NO’ provide a couple of normally
opened relay contacts.)
Relay 1: This relay is activated when the fire alarm is activated.
Contact Load: U~ 250V
Normal operation or
Spark detected
I 5A
power disconnected
c)Terminal 7 and 8 drive the electromagnetic valve of the diverter
2.2 Electric wring – J13 of the control box
a) Terminal 92
、
terminal 93 and terminal 94
,
a voltage-free contact is provided
that can be use to monitor the function status of the machine. In the default
configuration Relay 2 is configured as a Ready Relay.
Relay 2: Ready relay (Recommended warning output)
You can use this switching signal to activate a warning device or to stop the
material flow through the conveying line.
Contact Load: U~ 125V
Normal operation:
Error or power
I 0.6A
disconnected:
b) Terminal 95 and terminal 96 are connected to the Horn –strobe. Terminal 95 is
anode ,terminal 96 is cathode.
2.3 Electric wiring of the main board to the metal detector
The -X90 wiring terminals in the metal detector junction box is connected to the
control box main board through 2 shielded cables, in which the wiring
terminals
is connected to the transmitter cable (TX - cable) ;
The wiring terminals
is connected to the receiver cable (RX - cable).