background image

En-10

(2) Connect the connector.

Wire (louver): WHITE

Wire (display): WHITE

Wire (louver): RED

Indoor unit side

Arrange the wires as illustrated below.

• 

(3) Attach the connector cover.

Screw

Connector cover

7.3. Attach the intake grille

The installation is the reverse of “REMOVING THE INTAKE GRILLE”.

The intake grille can be rotated and installed 4 ways to suit the user’s preference.

CAUTION

The louver angle cannot be changed if the power is not on. (If moved by hand, it may 
be damaged.)

The grille assembly is directionally relative to the air conditioner body.

Install so that there is no gap between the grille assembly and the air conditioner body.

The cassette grille equips with an accessory to prevent the grill completely open. Be 
sure to read the INSTALLATION SHEET included with the cassette grille before instal-
lation.

8. FUNCTION SETTING

 CAUTION

Confi rm whether the wiring work for outdoor unit has been fi nished.

Confi rm whether the cap for electric control box on the outdoor unit is close.

This procedure changes to the function settings used to control the indoor unit according 

• 

to the installation conditions. Incorrect settings can cause the indoor unit malfunction.

After the power is turned on, perform the “FUNCTION SETTING” according to the instal-

• 

lation conditions using the remote controller.

The settings may be selected between the following two: Function Number or Setting 

• 

Value.

Settings will not be changed if invalid numbers or setting values are selected.

• 

Refer to the installation manual enclosed with the remote controller when the wired 

• 

remote controller (option) is used.

8.1. Operation method

While pressing the FAN button and SET TEMP. (

• 

) simultaneously, press the RESET 

button to enter the function setting mode.

STEP 1
Selecting the Remote Controller Signal Code

Use the following steps to select the signal code of the remote controller.
(Note that the air conditioner cannot receive a signal code if the air conditioner has not 
been set for the signal code.)
The signal codes that are set through this process are applicable only to the signals in 
the FUNCTION SETTING. For details on how to set the signal codes through the normal 
process, refer to SELECTING THE REMOTE CONTROLLER SIGNAL CODE.

(1)  Press the SET TEMP. (

) (

) button to change the signal code between 

Match the code on the display to the air conditioner signal code. (initially set to 

) (If 

the signal code does not need to be selected, press the MODE button and proceed to 
STEP 2.)

(2)  Press the TIMER MODE button and check that the indoor unit can receive signals at 

the displayed signal code.

(3) Press the MODE button to accept the signal code, and proceed to STEP 2.

The air conditioner signal code is factory-set to A .
Contact your retailer to change the signal code.

The remote controller resets to signal code A when the batteries in the remote controller 
are replaced. If you use a signal code other than signal code A, reset the signal code 
after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the signal codes 
(

) until you fi nd the code which operates the air conditioner.

STEP 2

Selecting the Function Number and Setting Value

(1)  Press the SET TEMP. (

) (

) buttons to select the function number. (Press the 

MODE button to switch between the left and right digits.)

(2)  Press the FAN button to proceed to setting the value. (Press the FAN button again to 

return to the function number selection.)

(3)  Press the SET TEMP. (

) (

) buttons to select the setting value. (Press the MODE 

button to switch between the left and right digits.)

(4)  Press the TIMER MODE button, and START/STOP button, in the order listed to 

confi rm the settings.

(5) Press the RESET button to cancel the function setting mode.
(6)  After completing the FUNCTION SETTING, be sure to turn off the power and turn it on 

again.

Function number 

Setting value

 CAUTION

After turning off the power, wait 30 seconds or more before turning on it again. The 
FUNCTION SETTING doesn’t become effective if it doesn’t do so.

8.2. Function setting

(1) Filter sign

The indoor unit has a sign to inform the user that it is time to clean the fi lter. Select the 
time setting for the fi lter sign display interval in the table below according to the amount 
of dust or debris in the room. If you do not wish the fi lter sign to be displayed, select the 
setting value for “No indication”.

9379124010-05_IM.indb   10

9379124010-05_IM.indb   10

8/31/2012   10:43:29 AM

8/31/2012   10:43:29 AM

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Summary of Contents for AUYG14LVLB

Page 1: ...βις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CONDITIONER INDOOR UNIT Compact Cassette Type h c s t u e D s i a ç n a r F l o ñ a p s E o n a i l a t I ά k I v η λ λ E s ê u g u t r o P h s i l g n E e ç k r ü T й и к с с у Р PART NO 9379124010 05 9379124010 ...

Page 2: ...eration cycle will become abnormally high and cause the piping to rupture If there is a refrigerant leak make sure that it does not exceed the concentration limit If a refrigerant leak exceeds the concentration limit it can lead to accidents such as oxygen starvation Do not touch refrigerant that has leaked from the refrigerant pipe connections or other area Touching the refrigerant directly can c...

Page 3: ...ssette grille Hook wire 2 For suspending the Cassette grille Screw pitch small M4 10 mm 2 For mounting the Hook Wire for metals Screw pitch large M4 10 mm 4 For mounting the L angle and Hook wire for resins 2 5 Optional parts Parts name Model No Summary Wired remote controller UTY RNN M Unit control is performed by wired remote controller Simple Remote Controller UTY RSN M For air conditioner oper...

Page 4: ...ong and durable ceiling 262 or more 1 000 or more 1 800 or more 1 000 or more Unit mm Floor Obstruction This product can be installed at a height of up to 3 000mm However 7000 9000 Btu h model can not be installed in high places Perform the Function Setting on the remote control in accordance with the installed height See 8 2 Function setting Discharge direction setting The discharge direction can...

Page 5: ...p Air bleeding When lifting up drain Height of inclined pipe should be less than 700 mm from the ceiling A rise dimension over this range will cause leakage Lift up the pipe vertically at the position of 300 mm or less from the unit 300 mm or less VP25 O D 32 mm local arrangement 700 mm or less Horizontal or upward gradient Downward gradient 1 100 to 1 50 VP30 O D 38 mm or more Downward gradient 1...

Page 6: ...flare tool exclusive for R410A 1 Cut the connection pipe to the necessary length with a pipe cutter 2 Hold the pipe downward so that cuttings will not enter the pipe and remove any burrs 3 Insert the flare nut always use the flare nut attached to the indoor and outdoor units respectively onto the pipe and perform the flare processing with a flare tool Leakage of refrigerant may result if other fla...

Page 7: ...nnections Improp erly connected or secured wires can cause serious accidents such as overheating the terminals electric shock or fire Do not modify the power cables use extension cables or use any branches in the wir ing Improper connections insufficient insulation or exceeding the allowable current can cause electric shock or fire Match the terminal block numbers and connection cable colors with ...

Page 8: ...R UNIT R W B Red White Black Wired remote controller cable Indoor unit Remote controller cable Earth Ground the remote controller if it has a earth ground line Wired remote controller R W B Simultaneous twin 18 22 24 type only Connection cable Indoor unit Primary Indoor unit Secondary Junction box Lo cal purchase Outdoor unit Earth Ground line Control line Power line Earth Ground line Wired remote...

Page 9: ...ires Power supply cable or connection cable 20 mm 40mm or more Earth ground wire Use a 4 core wire cable 5 3 Connection of wiring 1 Remove the control box cover and install each connection wire Screw Control box cover 2 After wiring is complete secure the remote controller cable and transmission cable with the attached the cable tie and the clamper Detail a a Wire clamper accessory Bind securely T...

Page 10: ... Select a place that will not be affected by the heat from a stove etc Install the remote controller with a distance of 7 m between the remote controller and the photocell as the criteria However when installing the remote controller check that it operates positively Install the remote controller holder to a wall pillar etc with the tapping screw Mount the holder 1 Screws Set the remote controller...

Page 11: ...through the normal process refer to SELECTING THE REMOTE CONTROLLER SIGNAL CODE 1 Press the SET TEMP button to change the signal code between Match the code on the display to the air conditioner signal code initially set to If the signal code does not need to be selected press the MODE button and proceed to STEP 2 2 Press the TIMER MODE button and check that the indoor unit can receive signals at ...

Page 12: ...or or remote controller unit sensor 8 Wireless remote controller signal code Change the indoor unit Signal Code depending on the wireless remote controllers Factory setting Setting description Function number Setting value A 44 00 B 01 C 02 D 03 9 External input control Operation Stop mode or Forced stop mode can be selected Factory setting Setting description Function number Setting value Operati...

Page 13: ...supply cable Bus wire Remote controller cable Indoor unit 1 primary Indoor unit 2 secondary Indoor unit 3 secondary Set the R C address DIP switc h setting 2 Set the R C address of each indoor unit using the DIP switches on the indoor unit circuit board See the following table and figure The DIP switches are normally set to make the R C address 00 Indoor unit R C address DIP SWITCH No 1 2 3 4 1 00...

Page 14: ...roller setting 4 Set the indoor unit that is connected to the outdoor unit using a transmission cable as the primary Function Number Setting Value Primary 51 00 Secondary 01 After completing the function settings turn off all of the indoor units and then turn them back on If error code 21 22 24 or 27 is displayed there may be an incorrect setting Perform the remote controller setting again NOTE Wh...

Page 15: ...ted Indoor unit remote controller com munication error 10 CHECK LIST Pay special attention to the check items below when installing the indoor unit s After installation is complete be sure to check the following check items again CHECK ITEMS If not performed correctly CHECK BOX Has the indoor unit been installed correctly Vibration noise indoor unit may drop Has there been a check for gas leaks re...

Page 16: ...rror 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor error 8 2 Sub cool Heat Ex gas inlet temp sensor...