Chapter 2 - Installation
LED
Function
Status
Description
Off
Data rate is 10 Mbps on the
corresponding LAN port.
On
The ODU port is connected to the ODU.
ODU LINK/ACT
ODU Port
Activity
Blinking
The ODU port is sending or receiving
data.
On
Data rate is 100 Mbps.
ODU 10/100
ODU Port Data
Rate
Off
Data rate is 10 Mbps.
ODU WLINK
ODU Wireless
Link Status
On
The ODU is connected with an AU.
2.2.1.2
RESET ROUTER Button
Press momentarily the recessed RESET ROUTER button to reset the
Networking Gateway IDU.
2.2.1.3
Resetting the IDU to Factory Defaults
Press the RESET ROUTER button for at least 5 seconds, until the STATUS
LED flashes 5 times. After releasing the button, the unit will resume
operation with the factory default configuration.
Installation
12