MODEL 227
OPERATION MANUAL
Doc # 740063 Rev E
SECTION V - OPERATION
5.9
ROTATION CALIBRATION
NOTE
For proper operation, Weld Head rotation speed must be calibrated for the power
supply it is connected to. If weld heads are switched they must be re-calibrated on
that system before welding commences .
1. Insure that the weld head is connected per section III. Rotation calibration is
done by moving the torch and measuring actual speed. Before proceeding
CHECK THAT THE WELD IS FREE TO ROTATE SAFELY.
2. To manually calibrate the user will need to have a Weld Schedule in the Library
programmed in accordance to the Calibration Procedure contained in the
operation manual for the particular Weld Head being used.
3. A MANUAL calibration schedule will always be run in TEST Mode and usually
contains the following:
PRE-PURGE-POST
UP-SLOPE-DOWN
ROT-DLY
000 000
00.0 00.0
CCW 00.0
STR-WFDY-STP
RETRACT
T/MODE
00.0 00.0
0.0
AUTO
LVL TIME
PRI-AMP-BCK
PRI-PULSE-BCK
1 ***
000 000
0.00 0.00
LVL
PULSE
ROT
PRI--RPM--BCK
1
OFF
CONT
*** ***
LVL PRI-WF-BCK
1
000 000
LVL TIME
PRI-AMP-BCK
PRI-PULSE-BCK
2 005
000 000
0.00 0.00
LVL
PULSE
ROT
PRI--RPM--BCK
2
2
OFF
0.0 0.0
4. LEVEL 1 TIME needs to be set for the time it will take to rotate ONE
REVOLUTION at the selected LEVEL 1 PRI--RPM rate. The RPM rate is
usually set at a rate that the head is most frequently used at
LEVEL 2 is added with ROTATION turned OFF. This is to allow the operator
time to see if 1 revolution was completed before the “Return to Home”
functions engages at the end of the Sequence. LEVEL 2 CAN BE OMITTED
FOR WELD HEADS THAT DO NOT HAVE A RETURN HOME
FUNCTION .
5.14
Summary of Contents for 227
Page 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Page 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Page 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Page 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Page 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Page 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Page 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Page 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...