MODEL 227
OPERATION MANUAL
Doc # 740063 Rev E
SECTION V - OPERATION
5.6
OVERRIDING FUNCTION VALUES
4. When the new value is displayed and verified, press the ENTER key. The
function will stop blinking and the system is ready to change another value or
to operate.
5. MODES such as TIMER, ROT, etc. are not controlled by any limits and can be
changed overridden by the Operator by using the F key to change the MODE.
5.7
SET UP FUNCTIONS
There are two types of SET UP screens. Both are accessed with the SET UP key.
One type appears when the System Mode is set to Operate and both appear when
The System Mode is set to OPERATE and both appear when the System Mode is
set to PROGRAM.
NOTE
The SET UP screens offer special functions that can ENHANCE or in some cases
CHANGE the way the M-227 operates. It is important for the user to understand
these features. Under some conditions, if not properly set, undesirable performance
can occur.
1. OPERATE MODE SET UP FUNCTIONS - Pressing the SET UP key on the
M-227 panel when on the STATUS SCREEN or WELD SCREEN with the
System Mode set to OPERATE will access the first of three SET UP screens
that contain the following functions:
1. CALCULATE - Pressing the F key under this choice will access a prompt
screen for calculating Tungsten Length or RPM or Weld Time. Follow the
instruction on the screen to make these calculations. These features can be
very helpful when creating new weld procedures.
2. WELD SELECT - This feature is used to select up to 4 different weld
schedules to be accessible by M-227-RP Remote Pendant. Press the F key
under Weld Select and follow the instructions on the display.
3. COOLANT FAULT - If the Coolant Fault is ON the M-227 will look to see
if an optional M227/207-CW or M207-CW Cooling Unit is connected. If it is
then the M-227will require that coolant be flowing or else it will create a fault.
If for some reason the Cooling Unit is connected but not being used the
operator can change this Coolant Fault Set Up to OFF and no coolant fault will
be detected.
CAUTION
Severe damage to the weld head and cables can occur if you have the
Coolant Fault turned OFF and are operating a weld head that needs
coolant and then you forget to turn the cooler on or to make the connections.
5.7
Summary of Contents for 227
Page 13: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SYSTEM CONFIGURATON 1 7 ...
Page 22: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E INSTALLATON LOCATONS 3 4 ...
Page 23: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E AC POWER SET UP 3 5 ...
Page 24: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E CABLE CONNECTIONS 3 6 ...
Page 33: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E SEQUENCE TIMING CHART 4 7 ...
Page 34: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E PANEL KEY LOCATIONS 4 8 ...
Page 49: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E USE OF NEXT PREVIOUS KEYS 5 5 ...
Page 54: ...MODEL 227 OPERATION MANUAL Doc 740063 Rev E STANDARD REMOTE PENDANT 5 10 ...