This procedure calibrates the output current of the power supply. This is five-
point calibration procedure.
1. Close the switch between the power supply and the resistive load.
2. Connect the meter between the output and adjustable resistive load.
3. Set the voltmeter to read the AC current.
4. Ensure that load is connected to the output. Load setting should select range for 0
to 5Amps at 50Volts AC.
5. Issue clear and reset commands:
*CLS
*RST<n>
6. Set the voltage range of the power supply to high:
SOUR<n>:VOLT:RANGE 1
7. Set the OVP supervisory to limit 20261:
CAL<n>:OUTP:VOLT:PROT:COUNTS 20261
8. Set the OCP supervisory to maximum limit:
CAL<n>:OUTP:CURR:PROT:COUNTS 4800
9. Turn the unit on:
OUTP<n>:STATE 1
10. Set the output voltage to 50 Volts:
SOUR<n>:VOLT 50
11. Program the output current to 5% of the full scale current:
CAL<n>:OUTP:CURR:COUNTS 228
12. Wait for AC current to stabilize. Measure the output current using the AC meter.
Enter the measured current:
CAL<n>:OUTP:CURR:FIVEPOINT1 <value-1>
13. Program the output current to 27.5% of the full scale current:
CAL<n>:OUTP:CURR:COUNTS 1252
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...