ReFlex Power™
DC Power Supplies
M380056-01 Rev L
6-29
RFP-D2033-030-XXXX,
I
NTERFACE
C
ONNECTOR
:
External isolated digital and analog control interface.
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09
Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with
connector)
Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (recommended)
Maximum length 10 meters (can be extended subject to environment,
cable type, and interface circuits).
RFP-D2033-030-XXXX
I
NTERFACE
P
INOUT
Figure 6-7. RFP-D2033-030-XXXX Interface Connector, Front Panel View, and Wiring Diagram
Table 6-4. RFP-D2033-030-XXXX Interface Connector Pinout
PIN
NAME
FUNCTION
SIGNAL LEVEL
1
ENA
1
Input: module output enable
TTL logic level
6
ENA-RTN
1
Input: return for ENA signal; connected to Pin-7/8
Signal common
2
TRIG-OUT
Output: trigger output signal
TTL logic level
7
TRIG-OUT-RTN Output: return for TRIG-OUT; connected to Pin-6/8
Signal common
3
TRIG-IN
Input: trigger input signal
TTL logic level
8
TRIG-IN-RTN
Input: return for TRIG-IN; connected to Pin-6/7
Signal common
4
RESERVED
9
RESERVED
5
CHAS-GND
Shield ground
Chassis ground
1
Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is
pulled low (<= 0.5 V) with respect to the ENA RTN signal; this may also be accomplished by shorting Pin
1 to Pin 6.
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...