INTRODUCTION
4
1.
Introduction and Features
WALK-IN MONITORING SYSTEM 200 (WIMS 200) was designed by American Panel Corporation to
address multiple issues regarding walk-in units and to incorporate the functionalities of various walk-in door
devices in a single, flexible, reliable, and user friendly controller.
WIMS 200 features:
Walk-in Temperature Monitoring
Walk-in Temperature Alarms
External Alarm Output With Direct 115VAC, Up To 150W
Door Frame Heater Temperature Controlling
Door Frame Heater Temperature Monitoring
Real Time Clock And Date With Backup Battery And Automatic Recharge Function
Communication Protocol With Software For PC Connection (Optional)
SD/MMC Card With USB Adapter
HACCP Compliant Data Logger
Electronically Controlled Light Switch With Light On/Off Indicator
Automatic Light Off
External Switch Connection For CAL-OSHA Back-To-Back Light Control (Optional)
Multi-Way (3 Or 4 Ways) Light Control (Optional)
Panic Button (Optional)
Door Switch
Celsius Or Fahrenheit Temperature Selection
1.1.
Temperature Monitoring and Alarms
To efficiently monitor the walk-in air temperature, WIMS 200 is equipped with a highly accurate temperature
probe mounted inside the walk-in. The temperature readings are displayed on an ultra bright dot matrix LED
display.
The controller alarm system is comprised of a high and low temperature alarm with built in trigger delay to
allow small temperature fluctuations (occurring in daily walk-in operations such as door openings, door
closings, and evaporator defrost cycles) without triggering the alarms. The alarm’s set points and delay times
are fully programmable to the user’s needs.
In case the air temperature inside the walk-in is reaching an alarm condition, WIMS 200 uses visual and audible
alert methods. In addition to the integrated buzzer and alarm display message, the controller has a
120V/60Hz/150W output for additional external alarm devices (optional).
1.2.
Door Frame Heater Temperature Control and Monitoring
Door frame heater control and monitoring is done by two different methods that work in conjunction to save
energy and to maintain the door frame heater temperature within a preset range.
A temperature probe is mounted on the door frame heater wire to accurately monitor its temperature. Viewing
the door frame heater temperature is as easy as pressing a button.
Summary of Contents for Walk-in Monitoring System 200
Page 6: ...CONTROLLER 6 2 Controller...
Page 32: ...ELECTRICAL DIAGRAMS 32 13 Electrical Diagram 13 1 Wiring Diagram...
Page 33: ...ELECTRICAL DIAGRAMS 33...
Page 34: ...ELECTRICAL DIAGRAMS 34...
Page 35: ...ELECTRICAL DIAGRAMS 35...
Page 36: ...ELECTRICAL DIAGRAMS 36 13 2 PC Connection Wiring Diagram...