10
American Dryer Corp.
450370 - 2
TO REPLACE BLOWER MOTOR CONTACTOR, 24 VAC
1. Discontinue power to the dryer.
2. Remove all wires from contactor (NOTE: make sure each
wire is marked with location removed from).
3. Press down firmly on the contactor and shift towards the
right, then pull contactor out.
4. Install the new contactor in reverse procedure.
5. Reestablish power to the dryer.
Burner Controls (Gas)
This illustration is typical of all gas burners, but they are not all
exactly alike. Your particular model may have some differences.
AD45x2R
4. Disconnect sensor bracket harness connector.
5. Disassemble the sensor probe from the bracket assembly
by removing the top push on fastener securing the probe
to the bracket. Use a small screwdriver to slowly pry the
fastener off.
6. Install new sensor probe assembly by reversing the
procedure.
7. Reestablish power to dryer.
NOTE:
If, when power is reestablished the computer
display reads “exhaust probe fault”, check for loose
connection on the wiring.
AD45x2R
TO REPLACE COMPUTER
TEMPERATURE SENSOR PROBES
1. Discontinue power to the dryer.
2. Open lint door to gain access to sensors.
3. Remove the screws holding the sensor in place.
AD30x2R