Summary of Contents for 31-16073

Page 1: ...quires basic mechanical and electrical skills J it is your responsibiliW to contact a qualified installer to make the electrical onnect _o_n__S J TOOLS YOU WiLL NEED SLiP JOINT PLIERS FLAT BLADE SCREWDRIVER PHiLLiPS SCREWDRIVER MATERIALS YOU WiLL NEED DiA METAL DUCT RECOMMENDED 4 DUCT CLAMPS 2 OR 4 SPRING CLAMPS 2 4 DIA FLEXIBLE METAL DUCT_ IFNEEDED 4 DIA METAL ELBOW DUCT TAPE EXHAUST HOODSAFETY G...

Page 2: ...rotected by the required time delay fuses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required If the electric supply does not meet the above specifications then call a licensed electrician GROUNDING iNSTRUCTiONS This dryer must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the cir...

Page 3: ...st longer than specified length will Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty The MAXIMUM ALLOWABLE length of the exhaust system depends upon the type of duct number of turns the type of exhaust ho...

Page 4: ...STRUCTIONS iN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented at floor level FOR STRAIGHT LINE iNSTALLATiON CONNECT THE DRYER EXHAUST TOTHE EXTERNAL EXHAUST HOOD USING DUCT TAPE ORCLAMP CORD NOT SUPPLIED WITH DRYER CUTTHEMETALEXHAUST DUCT NOTSUPPLIED TOTHE PROPER LENGTH NOTE WESTRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING HOWEVER IFFLEXIBLE DUCTI...

Page 5: ...n dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area e...

Page 6: ...sing a flat blade screwdriver RIGHT OR LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SiDE OF CABINET Preassemble 4 elbow with 4 duct Wrap duct tape ...

Page 7: ...re to get the screw started 2 Loosen the top screws from each hinge on the dryer face half way With one hand holding the top of the door and the other hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180 Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top ...

Page 8: ...Notes ...