Page 1: ...here it will be exposed to water and or weather The National Fuel Gas Code restricts installations of gas appliances in garages They nmst be 18 in off the ground and protected by a barrier from vehicles Install the dryer where the temperature is above 50 F lot satisfactory operation of the dryer control system n u I In the state of Massachusetts Installation must be performed by a qualified or lic...

Page 2: ...on must be installed imme diately upstream of the gas supply connection to the dryer Contact your local gas utility should you have questions on the instailation of the plugged tapping Supply line is to be 1 24n rigid pipe and equipped with an accessible shut off within 6 fL of and in the same room with the drver Ese pipe thlead sealer compound appropriate for natural or LP gas or use bflon tape T...

Page 3: ...PIPE SIZE ATLEAST 1 2 3 APPLY PIPE COMPOUND TOALLMALE THREADS TIGHTEN ALLCONNECTIONS USING TWO ADJUSTABLE WRENCHES DONOT OVERTORQUE GASCONNECTIONS LEAK TEST _kWARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS OPEN _I GAS VALVE _ Check al connections for leaks with soapy _ oludcm or equivalent Apply soap solution Leak test solution must not contain ammooia which could cause damage to the brass ...

Page 4: ... noted below Boih rigid and flexible metal duct are shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Recommended 4 _ 4 i 4 No of 90 Rigid Flexible Elbows Metal Metal 0 90 Feet 55 Feet t 60 Feet 40 Feet 2 45 Feet 30 Feet 3 35 Feet 20 Feet If using flexible metal duct please refer to page 6 Use only for short run installations 4 DIA IL _ 4 2 1 2 Rigid Flexible Me...

Page 5: ...HIS WILL PERMIT DIRECT ACCESS FOREASIER EXHAUST CONNECTION THIS DRYERCOMES READY FOR REAREXHAUSTING IF SPACEIS LIMITED USE THE INSTRUCTIONS IN SECTION 12 TO EXHAUST DIRECTLYFROM THE LEFTSIDE OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST WESTRONGLY RECOMMEND THE USEOF RIGID METAL EXHAUST DUCT iFUSING FLEXABLE METAL DUCT CUT tTTOTHE PROPER LENGTH ANDAVOID BUNCHING OFTHE DUCT BEHIND THE DRYER FOR ST...

Page 6: ...t be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line No other fuel burning appliance shall be installed in th...

Page 7: ...de screwdriver 7 ADDING NEW DUCT FIXING HOLE PORTION A i LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower 1 musing Make sure that the fi dng hole is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO SIDE OF CABINET Pre assemble 4 elbow with 4 duct Wrap duct ta...

Page 8: ...n the top screws from each hinge on the dryer lace half way With one hand holding the top of the door and the other hand holding the bottom remove the door t om the dryer by lifting it UP and OUT 3 Rotate the door 180 Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step t 4 Remove ...