H. Drive motor operates in forward mode, but does not
reverse, blower motor runs. The display reads
“Rotation Fault”*. (Refer to page 20)
1. Possible causes:
a. Belt is loose or slipping.
b. Rotational sensor is out of adjustment.
c.
Check for 24 VAC at the computer board J8
connector pin 9 gray wire to GND. If no voltage is
present, check for a loose connection, if connection
is good, replace computer. If voltage is present,
proceed to next step.
2. Check for 24 VAC on the drive motor contactor CR3 A1 to
A2. If no voltage, check for a loose connection. If voltage
is present, proceed to next step.
3. Check for proper voltage on the CR3 and T2 of the drive
contactor. If no voltage, replace drive contactor.
4. Check for a loose connection to motor, if no loose
connection, replace motor.
I.
The display reads “Cycle Paused, Main Door Open”.
(Refer to page 20)
1. Make sure main door is closed.
2. Make sure main door has good contact with the main door
switch.
3. Check for voltage (24 VAC) at the computer board J8
connector pin 5. If no voltage, check for a loose connection
or change the computer board. If voltage is present,
proceed to Step #4.
4. Check for voltage to the main door switch. If voltage is
present check that the switch has continuity when
depressed, if not replace switch. If switch has continuity
proceed to Step #5.
5. Check for voltage (24 VAC) at the computer board J8
connector pin 6. If no voltage, check for a loose connection
between the switch and the computer. If voltage is present
change the computer board.
J. The display reads “Cycle Paused, Lint Access
Open”. (Refer to page 20)
1. Make sure lint drawer is closed.
2. Make sure lint drawer has good contact with the switch.
3. Check for voltage (24 VAC) at the computer board J8
connector pin 3. If no voltage, check for a loose connection
or change the computer board. If voltage is present,
proceed to Step #4.
4. Check for voltage to the lint drawer switch. If voltage is
present check that the switch has continuity when
depressed, if not replace switch. If switch has continuity
proceed to Step #5.
5. Check for voltage (24 VAC) at the computer board J8
connector pin 4. If no voltage, check for a loose connection
between the switch and the computer. If voltage is present
change the computer board.
NOTES ______________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________
_____________________________________________________________