38
RG500 Series
The MAX SPD setting determines the maximum motor speed in the
forward and reverse direction when the speed adjust potentiometer or
input voltage signal is set for maximum speed.
To calibrate MAX SPD:
1. Set the speed adjust potentiometer or input voltage signal for
maximum speed.
2. Adjust MAX SPD until the desired maximum speed is reached.
Note: Check the MIN SPD and MAX SPD adjustments after recalibrating
to verify that the motor runs at the desired minimum and maximum
speed.
Note: If using models RG500UA-PCM or RG510UA-PCM, set the MIN
SPD to full CCW and the MAX SPD to full CW. Use the MIN OUT and MAX
SPD trim pots located on the top board for minimum and maximum
speed calibration. See page 45 for calibration of those trim pots.
Maximum Speed (MAX SPD)
The MIN SPD setting determines the minimum motor speed in
unidirectional operation when the speed adjust potentiometer or input
voltage signal is set for minimum speed.
To calibrate the MIN SPD:
1. Set the speed adjust potentiometer or input voltage signal for
minimum speed.
2. Adjust MIN SPD until the desired minimum speed is reached or
is just at the threshold of rotation.
Minimum Speed (MIN SPD)
Summary of Contents for Minarik DRIVES RG500 Series
Page 70: ...61 RG500 Series Notes...