28
RG500 Series
Set the input voltage select switches SW501 and SW502 to either 115 or
230 to match the AC line voltage. See Figure 14.
Select Switches
Input Voltage Select (SW501, SW502)
Set the armature voltage select switch SW503 to either 90 or 180 to
match the maximum armature voltage. See Figure 14.
Armature Voltage Select (SW503)
Figure 14. Select Switches
L1
L2
230V
L2
115V
GND
F1
F2
A2
A1
SW501
C504
TB501
C503
C505
TB502
IC502
IC501
C502
115
230
230
115
SW502
L1
L2
FU502
FU501
FAST ACTING
FUSES ONLY
S3 S2 S1 S0 RB1 RB2 -15 +15 T1 T2
INHIBIT
SO501
INH-RUN
T505
SO502
T501
R501
C501
SCR501
SCR502
SCR503
SCR504
T502
T503
SCR505
SCR506
R504
R505
R506
T504
SCR507
SCR508
C509
C508
C507
C506
C510
SW504
SW503
ARMATURE
FEEDBACK
90
180
ARM
TACH
R502
R503
MIN SPD
FWD TQ
REV TQ
IR COMP MAX SPD FWD ACC REV ACC
DB
TACH
P501
P502
P503
P504
P505
P506
P507
P508
P509
Input Voltage
Select
(SW501, SW502)
Armature Voltage
Select (SW503)
Set the feedback select switch SW504 to either ARM for armature
feedback or TACH for tachogenerator feedback. See Figure 14.
Feedback Select (SW504)
Feedback Select
(SW504)
Summary of Contents for Minarik DRIVES RG500 Series