22
RG500 Series
+15 and -15
RG500 series drives can supply a reg15 and -15 VDC signal (each
sourcing 15 mA maximum) with respect to RB1, to isolated, external
devices. See Figure 10 for voltage supply terminal locations.
Do not short the +15 and -15 terminals for any reason.
Shorting
these terminals will damage the drive.
!
WARNING!
Enable, Regen Brake, and Inhibit
Direction Switch
For non -PCM models, refer to Figures 22 and 23 on page 50.
For -PCM models, a single-pole, single-throw switch can be used as a
reversal switch. Connect the switch to terminals COM and DIR. Close the
switch to reverse the motor. Open the switch to return the motor back to
it’s original direction. Refer to Figure 12 on page 25.
See the “Starting and Stopping Methods” section on pages 32 through 36
for a detailed description of the Enable, Inhibit, and Regen Braking (RB1,
RB2) connections.