18
RG500 Series
Speed Adjust Potentiometer
Use a 10K ohm, 1/4 W potentiometer for speed control. The motor can
operate in one direction (unidirectional) or two directions (bidirectional)
depending on how the speed adjust potentiometer is connected to the
drive.
For unidirectional operation in the foward direction, connect the speed
adjust potentiometer as shown in Figure 7(a).
For unidirectional operation in the reverse direction, connect the speed
adjust potentiometer as shown in Figure 7(b).
For bidirectional operation, connect the speed adjust potentiometer
as shown in Figure 7(c). The motor does not operate when the
potentiometer is in the center position. Turning the potentiometer
clockwise (CW) from the center position causes the motor to rotate in
the forward direction, while turning the potentiometer counterclockwise
(CCW) causes rotation in the reverse direction.
Figure 7. Speed Adjust Potentiometer Connections
S3
S2
S1
S0
CW
FWD
10K OHM
SPEED POT
S3
S2
S1
S0
CW
REV
10K OHM
SPEED POT
S3
S2
S1
S0
CW
REV
10K OHM
SPEED POT
FWD
(a). Unidirectional Forward
(b). Unidirectional Reverse
(c). Bidirectional
Summary of Contents for Minarik DRIVES RG500 Series
Page 70: ...61 RG500 Series Notes...