2
RG500 Series
Section 2. Specifications
Model
Maximum
Armature
Current (ADC)
HP Range
with 90 VDC
Motor
HP Range
with 180 VDC
Motor
Enclosure
RG510UA
RG510UA-PCM
RG510A
3.0
1/20 - 1/4
1/10 - 1/2
Chassis
Chassis
NEMA 4X
RG500UA*
RG500UA-PCM*
RG500A
10.0
1/8 - 1
1/4 - 2
Chassis
Chassis
NEMA 4X
* Heat sink kit part number 223-0235 must be used when the continuous
current output is over 7 amps.
AC Line Voltage
115/230 VAC ± 10% 50/60 Hz, single phase
DC Armature Voltage
with 115 VAC Line Voltage
with 230 VAC Line Voltage
0 - 90 VDC
0 - 180 VDC
Field Voltage
with 115 VAC Line Voltage
with 230 VAC Line Voltage
50 VDC (F1 to L1); 100 VDC (F1 to F2)
100 VDC (F1 to L1); 200 VDC (F1 to F2)
Maximum Field Current
1 ADC
Acceleration Time Range
0.5 - 15 seconds
Deceleration Time Range
0.5 - 15 seconds
Analog Input Range
Non -PCM models
(signal must be isolated; RB1 to S2)
Voltage Signal Range
PCM models
Voltage Signal Range
Current Signal Range
0 to ± 10 VDC
0 to ± 250 VDC
4 - 20 mA
Summary of Contents for Minarik DRIVES RG500 Series