RG500 Series
Section 6. Calibration
Dangerous voltages exist on the drive when it is powered. When
possible, disconnect the voltage input from the drive before
adjusting the trim pots. If the trim pots must be adjusted with
power applied, use insulated tools and the appropriate personal
protection equipment.
BE ALERT.
High voltages can cause serious
or fatal injury.
!
WARNING!
RG500 series drives have user-adjustable trim pots. Each drive is factory
calibrated to its maximum current rating. Readjust the calibration trim
pot settings to accommodate lower current rated motors.
All adjustments increase with CW rotation and decrease with CCW
rotation. Use a non-metallic screwdriver for calibration. Each trim pot is
identified on the printed circuit board.