Faults
114
Citan BAG0014.4 09.14
11
Faults
11.1
Indication of low seed hopper contents
When the seed level falls below the residual
amount (with properly adjusted seed level sen-
sor) a waning alarm () appears in the AMATRON
3 / AMALOG
+
with an audible signal.
The residual amount should be sufficiently large
to avoid deviations in the application rate or now
sown areas.
11.2
Failure of AMATRON 3 during operation
Getting the machine in transport position and
immediately see the nearest authorised work-
shop.
1. Stop the tractor engine, apply the parking
brake and remove the ignition key.
2. Remove the guards of the electr.-hydr. con-
trol block.
3. Release the hydraulic valve.
3.1 Fold boom: Pull two valve pins (Fig.
126/1) out of the valves and rotate 45
degrees until they latch.
3.2 Track marker: Unscrew and remove
two valve pins (Fig. 126/2) from the
valves.
4. Advise persons to leave the danger area.
5. Fold in the machine with the aid of the trac-
tor control valves
yellow
and
green
.
6. Get the machine into road transport position
(see Seite 102).
7. Immediately see the nearest authorised
workshop.
Fig. 126
Danger!
•
Only in case of a failure of
AMATRON 3 fold the machine
in emergency mode.
•
Only actuate the tractor spool
valves within the tractor cab.
•
Before actuating the tractor
spool valves advise persons to
leave the danger area.
After repair
Get the two valve rods (Fig. 126/1) into normal
position.