![Amazone Avant 6002-2 Original Operating Manual Download Page 109](http://html1.mh-extra.com/html/amazone/avant-6002-2/avant-6002-2_original-operating-manual_2919707109.webp)
9.3.3 The TwinTeC coulter does not guide the seed precisely into the furrow
When the guide extension is worn, the seed is not guided into the furrow.
1.
Remove the hose
6
.
2.
Remove the bolt
7
.
3.
Remove the TwinTeC seed outlet
1
.
4.
Remove the bolt
2
.
5.
Replace the guide extension
3
.
6.
Install the bolt.
7.
To install the TwinTeC seed outlet,
place the guides
4
in the coulter bodies
5
.
8.
Install the bolt.
9.
Install the hose.
1
6 Nm
6
7
2
3
1 Nm
4
5
CMS-I-00003242
9.3.4 TwinTeC concave disc blocked
When the inner scraper is worn, the concave discs are blocked by adhering soil.
1.
Remove the hose
5
.
2.
Remove the bolt
6
.
3.
Remove the TwinTeC seed outlet
1
.
4.
Replace the inner scraper
2
.
5.
Install the bolt.
6.
To install the TwinTeC seed outlet,
place the guides
3
in the coulter bodies
4
.
7.
Install the bolt.
8.
Install the hose.
3
4
5
6
1
2
6 Nm
CMS-I-00003245
CMS-T-00006594-A.1
CMS-T-00006595-A.1
9 | Repairing the machine
Eliminating faults
MG6545-EN-II | B.1 | 22.07.2021