AMADOS-II DB 531.3 05.00
Fitting instructions
69
Fig. 4.6
lift arm
1
2
4.4.1
Fitting Sensor "Y" (operational
position)
-
Fit magnet (4.6/1) with the included bolt from non-
magnetic material, e. g. brass bolt or V4A, to a
implement part which changes its position from
transport- into operational position and vice versa, e.
g. tractor three-point hydraulics.
The red painted side of the magnets should
face in direction of the sensor.
-
Fit sensor (4.6/2) with the enclosed bracket to an
opposite lying firmly staying part of the machine. In
operational position of the machine the magnet should
be situated directly in front of the sensor. If the
machine is in operational position, the vertical arrow
lights up in the left hand edge of the display.
If the implement part to which the magnets
are fitted is moving from the operational
position by more than 40 mm from the
sensor then for an unmistakeable
recognition of the working position a se-
cond magnet should be fitted in the
direction of movement of the magnet
(Fig. 4.7).
If the machine is in transport position the
magnet should have a minimum spacing
of 40 mm from the sensor to unmistakeably
recognise that the machine is no longer in
operation position (Fig. 4.7).
I
I
I
or
wrong
correct
min. 40 mm
min. 40 mm
max. 40 mm
max. 40 mm
range of movement
of the magnet
in operational position
range of movement
of the magnet
in operational position
magnet in
transport position
(operational position off)
magnet in
transport position
(operational position off)