Hectare meter - Preparations for starting the operation
3.3.3.2.2 Calibrating distance sensor
For determening the actual forward speed "AMADOS-II"
required the value "Imp./100m", which sensor "X"
releases to "AMADOS-II" when driving down a calibration
distance of 100 m.
For entering the calibration value “Imp./100 m” two
possibilities are given:
•
the value “Imp./100 m” is known and is dialed via the
key board.
•
the value “Imp./100 m” is not known and will be
determined by driving down a pre-measured distance.
As the calibration figure "Imp./100m" is
ground dependent it is, in case of soil
types which are heavily deviating from one
another, recommended to determine the
calibration figure always newly.
1.
The value "Imp./100 m" is known
-
Press
(with stationary vehicle).
-
Dial the known value "Imp./100m" by keys
or
.
-
Dial the known value "Imp./100m" via the keys
or
.
-
Press key
. The dialed value will be stored.
-
Press key
once again and check the stored
value. The display should now show the dialed value.
2.
The value "Imp./100 m" is unknown:
-
Accurately measure a test distance of 100 m in the
field. Mark start and end point of the test distance.
100 m
0 m
-
Bring tractor with the implement to the start position.
-
Simultaneously press keys
and
-
Drive accurately the test distance from the starting- to
the end point (when starting the counter returns to
"0"). During this the display will show continuously
the determined number of impulses.
Display during calibrating
Error
km/h
1/min
-
Stop after 100 m. The display will now show the
number of impulses, which were determined when
driving the test distance (100 m) .
-
Press key
. The displayed determined value
(Imp./100 m) will be stored.
-
Press key
once again and check the stored
value. The display should now show the determined
value (Imp./100 m).
F