AMADOS-II DB 531.3 05.00
Seed drill - Putting to operation - Short instruction
29
3. Mode "2 bis 4"
Do not change the indications given in Modus 2 to
4.
4. Mode “5”
Enter “mode “5” to instruct “AMADOS-II” whether
while creating tramlines the seed rate adjustment
should be reduced or not.
-
Dial Mode “5” and
•
for seed drills w i t h o u t seed rate
reduction when creating tramlines dial for
the second figure the value “00”.
•
pneumatic seed drills w i t h seed rate
reduction when creating tramlines pre-
dial via the second figure the desired seed
rate reduction in [%] when creating tramlines.
Regarding this, please refer to table 3.5.
Table 3.5:
Mode "5", Seed rate reduction when creating
tramlines by pneumatic seed drills with seed rate
remote control
5. Mode "6"
Enter “mode “6” to instruct “AMADOS-II” whether
the seed drill has been equipped with (=01) or
without (=00) a seed rate remote control.
6. Switch off „AMADOS-II“ and connect it to
implement plug.
7. Switch on again “AMADOS-II”.
8. Compare the displayed and the actual gearbox
setting lever position with one another (only
applicable for seed drills w i t h seed rate
remote control) (regarding this, please refer to
para. 3.2.3.2).
9. Check "Imp./100m" and correct if necessary (by
direct entering of by calibration test run; see para.
3.2.3.3.1).
10. Check the working width and correct if necessary
(see para. 3.2.3.3.2).
11. Enter rated value for the seed rate (only for seed
drill with seed rate remote control) (see para.
3.2.3.3.3).
12. Before starting the operation conduct a calibration
test (see para. 3.2.3.3.4).
13. Program the tramlining rhythm (see para. 3.2.3.3.5).
14. When creating interval tramlines dial the lengths of
the sown and not sown areas (only for peg-wheel
metering seed drills (please refer to para.
3.2.3.3.6).
15. Conduct starting function. After having conducted
the start function the hectare meter-part area is
automatically returned to “0” (please refer to para.
3.2.4.1).
16. Advance tramline counter (see para.3.2.4.2).
17. Pre-dial the wanted speed for the blower fan
monitoring (only for pneumatic seed drills) (please
refer to para. 3.2.4.6.3).
18. Start sowing operation.
working-
width
[m]
Number
of sowing
coulters
Number of
tramline-
hoses
recommended
seed rate
reduction
[%]
48
4
8
60
4
7
48
6
12
6
60
6
10
36
4
11
44
4
9
36
6
17
4,5
44
6
14
32
4
12
40
4
10
32
6
19
4
40
6
15
24
4
17
30
4
13
24
6
25
3
30
6
20