Seed drill - Putting to operation - Short instruction
3.2.1
In General
3.2.1.1
AMADOS-II on/off switching
By pressing key
"AMADOS-II" is switched
o and by pressing key
it is switched off.
When switching on, the display briefly
shows the programing date of the computer
program.
Whenever the supply voltage drops to
below 10 volts, e. g. when starting the
tractor, the computer automatically
switches off. It has to be switched on again
as described above.
3.2.1.2
Dial implement-specific data (values)
or
By these keys the implement-specific data (values)
which are required for the "AMADOS-II" can directly be
dialed.
Always confirm dialed values by
Key
.
By the 1st pressing of the
or
the display advances by one position into the desired
direction.
By renewed pressure onto the key the display continues
to run until the key is released.
Confirm and store simultaneously all implement-specific
data which are required for monitoring the connected
machine always by pressing key
.
3.2.2
Putting to operation (short instruction)
Before starting to operate enter the
implement-specific data by pressing the
corresponding keys in the mentioned order
newly or check .
All data regarding implement type and
implement execution (Mode “1” to “6”)
may only be entered while the implement
plug is disconnected.
1. While implement plug is disconnected switch on
“AMADOS-II” (pls. refer to para. 3.2.1.1).
Initially the display shows the program
entering date. For the following period of
approx. 10 sec. then no entry is possible.
Thereafter automatically the error message
"13" is shown. After a waiting time of
approx. 15 seconds the mode "1" can be
dialed.
2. Mode "1"
The prevailing machine type is selected via the
coding "machine type" in mode "1". The coding
depends on the seed drill type (stud-metering
wheel or pneumatic seed drill) and on whether the
seed drill is equipped with or without markers.
If the seed drill is equipped additionally with an
electric seed rate remote control via "AMADOS-
II", also the desired step width (1%, 10%, 20% or
30%), with which the seed rate shall be set when
pressing the keys
+
or
is pre-
selected via the coding "machine type".
The coding to be selected may be taken from table
3.4.
Table 3.4:
Mode "1", coding "Machinery type seed drill"
I
I
Coding
Machinery type seed drill
Stud-wheel
Pneumatic
Marker change over
Step width
for electric
seed rate
remote
control by
"AMADOS"
with
without
with
without
1%
00
10
20
30
10%
01
11
21
31
20%
02
12
22
32
30%
03
13
23
33
F
F
I
F