background image

22 

PIX-25 

 
 

Diagnostics 

The diagnostic mode of the PIX-25 clock can be entered by removing the top 

cover and using the programming mode. 
4.

 

With the cover removed, press the 

PROGRAM

 button to begin 

programming mode and 

P1 TIME

 

will

 

appear. 

5.

 

Press the 

CHANGE

 button to change the current 

programming mode until the display shows 

P7 

DIAGNOSE

. See the following sections for specific 

diagnostics. 

6.

 

Press the 

PROGRAM

 button exit programming and return the clock back 

to normal operation. 

 

 

Main Board Version (

d

1

Use this test to check the firmware version of the main board (Freescale) 
microcontroller. 
1.

 

With the cover removed, press and hold the 

PROGRAM

 button to begin 

programming mode and 

P1 TIME

 will appear. 

2.

 

Press the 

CHANGE

 button to change the current programming mode until 

the display shows 

P7 Diagnose

3.

 

Press the 

ENTER

 button once to display 

d1 soft rev 

menu 

4.

 

Press the 

ENTER

 button once and the clock will 

display the current firmware version (see Figure 

example on right). 

5.

 

Press the 

ENTER

 button to go back to the 

d1 soft 

rev 

menu.

 

6.

 

Press the 

PROGRAM

 button to exit programming or press the 

CHANGE

 

button to go to the next diagnostic sub program menu.

 

 

 

LCD Test (

d

2

Use this diagnostic to check the PIX-25 LCD display by turning on all 

segments. 

1.

 

With the cover removed, press and hold the 

PROGRAM

 button to begin 

programming mode and 

P1 TIME

 will appear. 

2.

 

Press the 

CHANGE

 button to change the current programming mode until 

the display shows 

P7 Diagnose

    

: 866-487-4751

VISIT: WWW.TIMECLOCKEXPERTS.COM

Summary of Contents for PIX-25

Page 1: ...PIX 25 1 PIX 25 Atomic Time Clock Installation and Operation Guide TO PLACE AN ORDER CALL 866 487 4751 OR VISIT WWW TIMECLOCKEXPERTS COM...

Page 2: ...due to the clocks failure to properly receive the radio signal because of interference whatever may be the source of this interference are hereby expressly excluded The PIX 25 has the atomic clock rad...

Page 3: ...at P 58 16 Customize 17 Code Program Custom Printing P61 17 Setting Custom Print Symbol Printing P62 19 Diagnostics 22 Main Board Version d1 22 LCD Test d2 22 Show Number Printed d3 23 Clear Memory d4...

Page 4: ...e the unit on an uneven or tilted surface This may result in injuries due to the unit dropping or falling off Do not put a water filled container or a metal object on top of the unit If water is spill...

Page 5: ...PIX 25 5 Cover Removal 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Page 6: ...oam spacer white located under the print head Figure Release the printer carriage 4 After removing the foam spacer with the cover off plug in the clock Note Should the clock not power up verify that t...

Page 7: ...urrent time settings exit programming and return to the normal display or press the ENTER button to return to programming mode Note During programming the time should be set depending on the mode the...

Page 8: ...hen this setting is set to DISABLED the clock s time will not change for Daylight Saving 1 With the cover removed press and hold the PROGRAM button to begin programming mode and P1 TIME will appear 2...

Page 9: ...2 digit year month date 24hr 60th hr 15JAN27 14 25 Pr 3 2 digit year month date 24hr 100th hr 15JAN27 14 42 Pr 4 2 digit year month date 24hr 10th hr 15JAN27 14 4 Pr 5 2 digit year month date 24hr 60...

Page 10: ...utton to change the current programming mode until the display shows P5 OTHER 3 Press the ENTER button once and the clock will flash the P 51 submenu for language setting the 2nd line will display LAN...

Page 11: ...DIC DEC DEZ DIC DEZ 12 received RCVD RCBDO RECU EING RICEV RCBDO RCVD sent SENT ENVDO ENV AUSG SPED ENVDO SENT faxed FAXED FAX FAXE FAX FAX FAX FAXED void VOID ANLDO ANNUL LAGER ANNUL ANUL VOID paid P...

Page 12: ...er detection If your PIX 25 is not printing make sure you are triggering the paper sensor which can be changed with this parameter 1 With the cover removed press and hold the PROGRAM button to begin p...

Page 13: ...button to change the current programming mode so the display shows P 54 lead zero 5 Press the ENTER button once and the clock will start flashing the current LEADING ZERO setting OFF or ON The default...

Page 14: ...light Saving beginning or ending dates may require updating the system set Daylight Saving calendar The default start date setting March 08 2015 at 2 00AM which is the second Sunday of March 2015 If t...

Page 15: ...d go to the previous menu 11 Press the CHANGE button once to move to next menu for setting DST End Date Note In order for the Daylight Saving Time feature to function correctly both Begin and End date...

Page 16: ...nge the current setting if desired 7 Press the ENTER button once and the month will start flashing Press the CHANGE button to change the current month value if desired 8 Press the ENTER button once an...

Page 17: ...r removed press the PROGRAM button to begin programming mode and P1 TIME will appear 2 Press the CHANGE button to change the current programming mode until the display shows P6 customize See the follo...

Page 18: ...TH 12HR 60TH 24HR 60TH 12H 100TH 24H 100TH 24 60 SEC or NO TIME The user can set the print minutes from any of the following options 1 10th Minutes The minutes will be printed in 1 10 format which mea...

Page 19: ...hange the desired symbol for digit 1 7 Press the ENTER button once and the clock will show the symbol for digit 2 8 If desired press the CHANGE button to select the desired value for 2 9 Press the ENT...

Page 20: ...Hr and 60th Hr 59 38 82 100MIN 12H 12 Hr and 100th Hr 59 38 82 10MIN 24HR 24 Hr and 10th Hr 35 23 03 20MIN 24HR Skip Not Applicable 45 29 61 60MIN 24HR 24 Hr and 60th Hr 45 29 61 100MIN 24H 24 Hr and...

Page 21: ...0th hr 15 APR 13 1 45 R PM 2D YEAR SPACE MONTH SPACE DATE SPA CE 12HR60TH END 2digit Year Month Date 24hr 60th hr 15 APR 13 13 45 2D YEAR SPACE MONTH SPACE DATE SPA CE 24HR60TH END 4digit Year Month D...

Page 22: ...o begin programming mode and P1 TIME will appear 2 Press the CHANGE button to change the current programming mode until the display shows P7 Diagnose 3 Press the ENTER button once to display d1 soft r...

Page 23: ...oft rev sub menu 4 Press the CHANGE button until the clock will displays d3 num print see Figure example on right 5 Press the ENTER button once and the clock will display the total number of prints wi...

Page 24: ...on display atomic sync Enter 12 to turn off display atomic sync Enter 13 to reset 6 digit count Enter 32 to clear memory Enter 98 to clear all parameters plus the total print number Note FAQ If the A...

Page 25: ...ws d6 advance 5 Press the ENTER button once to enter the diagnostic mode The clock will prompt the user to enter a 2 digit code by first flashing the lefthand digit on the bottom line Change the first...

Page 26: ...may result in jams or damage to the clock Note Amano recommends using the manual print method see Setting the Print Method for large paper and transparent media printing Carbon Paper The PIX 25 clock...

Page 27: ...operly under the following conditions Inside a large building between tall buildings underground or in buildings without windows Close to overhead power lines TV stations and train cables Close to hom...

Page 28: ...nd arrows Step 4 Turn the knob on the cartridge clockwise one turn to take up any slack in the ribbon see right hand Figure Step 5 Stamp a card to check the printing quality and confirm that you have...

Page 29: ...ay The possible error messages are listed in the following table along with their probable causes and solutions Note An error message can be possibly cleared by pressing the Reset button The Reset but...

Page 30: ...ror reoccurs check the wires and cables to verify all components are connected properly Er 03 Home Position Sensor Unlock cover and remove Press the Reset button to reset the printer carriage and the...

Page 31: ...he clock has power from the AC power adapter the clock will have all functionality and the display will show the current time date weekday ink level atomic clock signal level etc Power Off Mode During...

Page 32: ...M see Figure 24 Hour Format In the 24 hour time format alias military time the hours will be displayed up to 23 The time after 12 hours would be considered PM For example 17 25 see Figure 5 25 PM 12 0...

Page 33: ...PIX 25 33 Figure PIX 25 Clock Bottom Figure PIX 25 Clock Back Removed for Wall Mounting 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Page 34: ...etect paper for printing P 54 LEADING ZERO Enable disable leading zero from being printed P 56 DST BEGIN DATE Change DLS start date from factory default setting P 57 DST END DATE Change DLS end date f...

Page 35: ...ng data and or clear custom data Warranty Notice Any claim for warranty expressed or implied due to the clock s failure to properly receive the radio signal because of interference whatever the source...

Page 36: ...PIX 25 rear mounting plate level on the wall using 10 wood screws not included or equivalent 3 Verify that the cable for the AC Power Adapter is plugged into the back of the PIX 25 before hanging it...

Page 37: ...PIX 25 37 Operation PIX 25 Views Figure Display View Figure 1 Internal View 866 487 4751 VISIT WWW TIMECLOCKEXPERTS COM...

Page 38: ...and ink capacity Need Ribbons Keys and Accessories Visit The Atomic Time Synchronization Indicator in the LCD Display indicates the status of the signal When you first receive the clock it may be nece...

Page 39: ...rmined by Amano Cincinnati Inc that the product has failed due to defects in materials and workmanship If the failure is for any other reason Amano Cincinnati Inc shall repair or replace the returned...

Page 40: ...ears Ambient Temperature 10 C to 45 C 14 F to 113 F Ambient Humidity 10 to 90 non condensing Clock Accuracy 3 seconds week on AC Power 10 seconds week on Lithium Dimensions 6 11 16 170 mm Wide X 6 7 1...

Page 41: ...ct for Product Notifications We contact our customers in case of product updates Owner Verification Registration can serve as verification of your ownership in the event of product theft or loss Effic...

Reviews: