Testing Ethernet Communication (Optional)
Required Items:
•
CAT5/6 Ethernet Cable
•
Laptop Computer Running Windows 7 or Windows 8
1. Locate the Ethernet Adapter extension tucked in the base
of the master/center cabinet [Figure 30].
2. Connect the Ethernet cable to the Ethernet adapter
extension.
3. Connect the other end of the Ethernet cable to the laptop
computer.
4. Launch
Command Prompt
on the computer by typing
CMD
in the '
Search programs and files
' field.
5. Enter the following command:
ping XXX.XXX.XXX.XXX,
where XXX.XXX.XXX.XXX is the IP address of the turnstile
[Figure 29].
6. A successful ping will result in the message shown in
[Figure 31]:
The following procedure is applicable to non-networked (standalone) turnstiles. For instructions on testing Ethernet
communication over a facility network, please refer to the
SU5000 User Guide
.
192.168.0.100 is the default IP address configured by Alvarado.
If the turnstile has been assigned a different network IP
address, ping that IP address instead. Contact your system
administrator for network information.