Supervisor 5000 Installation Instructions
Page 12
For assistance: [email protected] +1 (909) 591-8431 PUD3667R1-6
NOTE
Baseplate Installation (Optional)
Refer to Appendix C on Page 34 for 28" and 36" baseplate dimensions.
The baseplate enables installation of the SU5000 turnstile on a solid foundation without the need to drill holes into the concrete.
The baseplate also provides concealed conduit channels for wiring primary power, crossover communication, and access control.
Baseplates may be bridged together for multi-lane configurations. The following information will guide the installer in baseplate
installation:
1. Determine and mark the installation location.
2. Place the baseplate in the marked location.
3.
Determine how the primary power and access control wiring will be routed to the master and/or center cabinet. Most
commonly, the wiring is run into the baseplate through one of the side plates and routed to the master and/or center cabinet.
To remove the side plate, remove the four (4) screws as shown in [Figure 8].
4. Use the
center
cable channel to route the primary power, crossover cable, and access control wires as shown in [Figure 8].
5.
Mount the SU5000 cabinets to the baseplate at the anchor location using the supplied mounting bolts [Figure 8].
6. For multi-lane applications, bridge the baseplates using the supplied bridge support(s) and screws [Figure 8].
7. Reinstall the side plate(s).
Fig. 8
Baseplate
Holes for bridging
multiple baseplates
Anchor locations
Conduit holes for power and communication cables
(Use separate conduits for power and communication cables)