22
•
MN-35947
•
Rev 22
•
10/22
•
Combitherm® CT PROformance™ and CT Classic Series Installation Manual
Installation
POSITIONING ON SITE — 20-10 & 20-20 MODELS
Place the oven on a stable, non-combustible level horizontal
surface. Use the adjustable feet to level the unit if the fl oor is
uneven.
1.
Once the unit has been positioned properly beneath
a ventilation hood system, adjust the four outside feet
located on the outside corners of the base frame. Begin
with a 32mm (1.25") height (illustration 1) leveling the oven
from side-to-side and front-to-back (illustration 2).
N O T I C E
To ensure proper fit of the trolley, the overall height of the
oven must meet this specification:
Minimum: 79-7/8" (203 cm)
Maximum: 80-3/8" (204 cm)
In addition, the vertical distance from the bottom of the
door frame to the floor must meet this specificaiton:
Minimum: 8-1/4" (210mm)
Maximum: 8-3/4" (222mm)
2.
Roll the trolley into the oven and check the overall fit of the
trolley. Close the door and check fit. Make adjustments as
needed.
NOTICE:
Adjustable measurements are from the top of the leg fl ange to the bottom
of the leg square frame (see illustration 1). If measurements exceed 1.57"
(40mm) in height or trolley is not on a level and stable horizontal fl oor,
the following may occur:
• Improper sealing of the door sweep gasket to the trolley plate, or
heat strip.
• Trolley may not fi t properly.
}
1.18-1.57"
(30–40mm)
C - at bottom
of oven
A, B, D
108mm
Illustration 1
Illustration 2
SITE INSTALLATION