Configuration of the camera
GUPPY Technical Manual
V4.0.1
207
To store the current camera settings into a profile:
1.
Write the desired
ProfileID
with the
SaveProfile
flag set
2.
Read back the register and check the
ErrorCode
field
To restore the settings from a previous stored profile:
1.
Write the desired
ProfileID
with the
RestoreProfile
flag set
2.
Read back the register and check the
ErrorCode
field
To set the default profile to be loaded on startup, reset or initialization:
1.
Write the desired
ProfileID
with the
SetDefaultID
flag set
2.
Read back the register and check the
ErrorCode
field
To go back to the factory default profile:
1.
Select ProfileID= 0 and toggle the
SetDefaultID
flag set
2.
Read back the register and check the
ErrorCode
field
Error codes
Reset of error codes
The
ErrorCode
field is set to zero on the next write access.
You may also reset the
ErrorCode
•
by writing to the
USER_PROFILE
register with the
SaveProfile
,
RestoreProfile
and
SetDefaultID
flag not set.
•
by writing 00000000h to the
USER_PROFILE
register.
ErrorCode #
Description
0x00
No error
0x01
Profile data corrupted
0x02
Camera not idle during restore operation
0x03
Feature not available (feature not present)
0x04
Profile does not exist
0x05
ProfileID out of range
0x06
Restoring the default profile failed
0x07
Loading LUT data failed
0x08
Storing LUT data failed
Table 109: User profile: Error codes