Outputs
The standard Guppy camera has 3 inverting outputs.
Output features are configured by software. Any signal can be placed on any
output.
The main features of output signals are described below:
Note
L
•
This feature works with external Trigger_Mode_0 only.
Outputs
Operating Conditions
Output voltage
0 ... 5.5 V
Output current
Max.
±
20 mA
Table 44: Output characteristics
Signal
Description
IntEna (Integration Enable) signal
This signal displays the time in which exposure
was made. By using a register this output can be
delayed up to 1.05 seconds.
Fval (Frame valid) signal
This feature signals readout from the sensor. This
signal Fval follows IntEna.
Busy signal
This signal appears when:
•
the exposure is being made or
•
the sensor is being read out or
•
data transmission is active.
Table 45: Output signals