Camera Link registers
92
Goldeye Camera Link Register Controls Reference V1.0.0
RegBCDatasetCount
Number of background correction datasets stored.
RegBCState
Shows the current state of the background correction processing. If the state is Ok
then the BC is operating normally as configured with
BCMode
, otherwise the ROI
settings might be out of range, a new integration might be needed or is still in
progress.
Register name
RegBCDatasetCount
Register type
IntReg
Access mode
R
Address
0x00090408
Length (Bytes)
4
Bits used
31..0
Register name
RegBCState
Register type
IntReg
Access mode
R
Address
0x000904BC
Length (Bytes)
4
Bits used
31..0
Enumeration values:
Value
Name and description
0
Ok
Correction operates normally.
1
DatasetInvalid
The current data set is not valid. Select a different data set, start a new
integration or wait until the current integration has finished.
2
ROIOutOfBounds
The current data set is valid, but at least one of the ROI settings has left
the data set's ROI. Change
Height
,
Width
,
OffsetX
or
OffsetY
accordingly, select a different data set or start a new integration.