Camera Link registers
50
Goldeye Camera Link Register Controls Reference V1.0.0
AnalogControl
Controls in this category describe how to control the sensor's analog
functionalities.
RegSensorGain
Sets the FPA gain level.
Register name
RegSensorGain
Register type
IntReg
Access mode
R/W
Address
0x000B0094
Length (Bytes)
4
Bits used
31..0
Enumeration values:
Value
Name and description
0
Gain0
(Default)
Sets FPA gain to lowest level
1
Gain1
Sets FPA gain to a higher level than Gain0 (if available)
2
Gain2
Sets FPA gain to a higher level than Gain1 (if available)