Camera Link registers
57
Goldeye Camera Link Register Controls Reference V1.0.0
RegRelativeHumidity[ ]
Relative humidity, measured at the location selected in
DeviceRelativeHumiditySelector
.
RegRelativeHumidityInq...
Determines the location(s) for measuring relative humidity provided by the
camera.
Register name
RegRelativeHumidity[]
Register type
Array of FloatReg
Access mode
R
Unit
Percent
Address
0x00024004 for
RelativeHumiditySensor
0x00024008 for
RelativeHumiditySensorBoard
0x0002400C for
RelativeHumidityMainBoard
Length (Bytes)
4
Bits used
31..0
Register name prefix
RegStatusRelativeHumidityInq...
Register type
IntReg
Access mode
R
Address
0x00024000
Length (Bytes)
4
Bits used
31..29
Bit assignment:
Bit
Name and description
29
...MainBoard
Contains
1
if a humidity sensor is present on the camera's mainboard.
30
...SensorBoard
Contains
1
if a humidity sensor is present on the camera's sensor
board.
31
...Sensor
Contains
1
if a humidity sensor is present on the camera's image
sensor.