Camera Link registers
54
Goldeye Camera Link Register Controls Reference V1.0.0
RegSerialPortBaudRate
Controls the data transmission rate used by the selected serial port. Note that
exactly one bit must be set.
Register name
RegSerialPortBaudRate
Register type
IntReg
Access mode
R/W
Address
0x0000B004
Length (Bytes)
4
Bits used
31..0
Bit assignment:
Bit
Name and description
0
Baud9600
If 1, serial port runs at 9.600 bits per second.
1
Baud19200
If 1, serial port runs at 19.200 bits per second.
2
Baud38400
If 1, serial port runs at 38.400 bits per second.
3
Baud57600
If 1, serial port runs at 57.600 bits per second.
4
Baud115200
If 1, serial port runs at 115.200 bits per second.
5
Baud230400
If 1, serial port runs at 230.400 bits per second.
6
Baud460800
If 1, serial port runs at 460.800 bits per second.
7
Baud921600
If 1, serial port runs at 921.600 bits per second.