AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
145
Starting a Local Management Session
To start a local management session on the switch, perform the following
procedure. If the switch is powered off, start with step 1. If the switch is
already powered on, start with step 3:
Note
The initial management session has to be a local session because
the AlliedWare Plus operating software does not come with a default
IP address.
1. Power on the switch by doing one of the following:
If the switch has an AC power supply, connect the AC power cord
to the power supply on the back panel and to an AC power source.
if the switch has two power supplies, you need to power on only
one of them for this procedure.
If the switch has the AT-SBxPWRSYS1-80 DC Power Supply,
power on the DC circuit and the On/Off switch on the power supply.
(If you have not yet wired the DC connector on the power supply,
refer to “Powering On AT-SBxPWRSYS1-80 DC Power Supplies”
on page 110.)
2. Wait three minutes for the switch to initialize the management
software.
3. Connect the RJ-45 end of the management card included with the
switch to the Console RS-232 port on the management panel. Refer to
Figure 95.
Summary of Contents for AT-FAN08
Page 10: ...Figures 10...
Page 12: ...Tables 12...
Page 16: ...Preface 16...
Page 38: ...Chapter 1 Overview 38...
Page 60: ...Chapter 2 Virtual Chassis Stacking 60...
Page 82: ...Chapter 4 Installing the Chassis 82 Figure 34 Example of Adjusting the Equipment Rack Brackets...
Page 104: ...Chapter 4 Installing the Chassis 104...
Page 140: ...Chapter 5 Powering On the Chassis 140...
Page 166: ...Chapter 7 Cabling the AT XEM2 Line Card Ports 166...