AT-DC2552XS / L3 Enterprise Core Switch Installation Guide
63
Note
If a new AT-PWR06 power supply module is not available to replace
the module you are removing, perform the procedure outlined in
“Installing Power Supply Blank Cover” on page 63.
4. Slowly insert the new AT-PWR06 power supply module into the PSU
slot until it is flush with the rear of the chassis.
5. Tighten the captive screws to fasten the power supply module to the
chassis.
6. Turn the power on to the newly installed AT-PWR06 power supply
module by connecting the AC power cord.
Installing Power
Supply Blank
Cover
If you have removed an AT-PWR06 power supply module from the
chassis, and a replacement power supply module is not available, the
blank power supply cover should be installed to insure proper airflow in the
chassis.
Caution
The PSU blank cover should be installed if an AT-PWR06 power
supply module is not installed in the power supply slot. This blank
cover assures correct airflow across the components within the
chassis when a power supply module is not installed.
Perform the following procedure to install the blank power supply cover:
1. Locate the blank power supply cover that was originally shipped with
the chassis.
2. Remove the AT-PWR06 power supply module by following Step 1 -
Step 3 in “Replacing Power Supply Module” on page 62.
3. Once the AT-PWR06 power supply module has been removed, place
the blank power supply cover over the vacant power supply slot.
4. Tighten the captive screws on the power supply blank cover.
Summary of Contents for AT-DC2552XS
Page 1: ...613 002097 Rev A AT DC2552XS L3 ENTERPRISE CORE SWITCH Installation Guide...
Page 8: ...Figures 8...
Page 10: ...Tables 10...
Page 14: ...Preface 14...
Page 34: ...Chapter 1 Overview 34...
Page 44: ...Chapter 2 VCStack Overview 44...
Page 86: ...Chapter 7 Managing the Switch 86...
Page 90: ...Chapter 8 Troubleshooting 90...