Chapter 4: Installing the Switch and Modules
60
Installing and Replacing AT-PWR06 Power Supply Module
The AT-PWR06 power supply module may be installed in one of the two
power supply slots - PSU1 or PSU2. See Figure 2 on page 22 for the
location of these slots.
The AT-DC2552XS / L3 Enterprise Core Switch can operate under full
load with one power supply module installed. However, if you want power
supply redundancy, a second power supply may be installed.
There is no functional difference between the two available power supply
slots. Operation of the AT-DC2552XS / L3 is the same when installed in
either slot. If you want to use only one power supply, Allied Telesis
recommends that you install it in the PSU1 slot.
The following procedures are included in this section:
“Installing Power Supply Module”
“Replacing Power Supply Module” on page 62
“Installing Power Supply Blank Cover” on page 63
Installing Power
Supply Module
Install the AT-PWR06 power supply module by performing the following
procedure:
1. Identify the power supply slot where you are installing the AT-PWR06
power supply module.
2. Loosen the captive screw on the blank cover panel of the power
supply slot blank cover and remove the cover. See Figure 24.
Figure 24. Loosen Power Supply Captive Screws
3. Store the blank cover in a safe place for future use.
Summary of Contents for AT-DC2552XS
Page 1: ...613 002097 Rev A AT DC2552XS L3 ENTERPRISE CORE SWITCH Installation Guide...
Page 8: ...Figures 8...
Page 10: ...Tables 10...
Page 14: ...Preface 14...
Page 34: ...Chapter 1 Overview 34...
Page 44: ...Chapter 2 VCStack Overview 44...
Page 86: ...Chapter 7 Managing the Switch 86...
Page 90: ...Chapter 8 Troubleshooting 90...